Leave Your Message
ALBO Residual Current Operated Circuit Breaker(RCBO)
RCBO

ALBO Residual Current Operated Circuit Breaker(RCBO)

The ALBO RCBO is a compact integrated safety device designed for 230V AC systems, ideal for both household installations and large-scale commercial/engineering projects. It offers protection against ground faults, overloads, and short circuits, with residual current sensitivity as low as 10mA and tripping within 0.1 seconds. Supporting both B and C characteristics and rated currents from 3A to 40A, with a 6kA breaking capacity and full compliance with EN IEC 61009-1, it occupies two modules on a DIN rail and includes clear wiring and torque guidance for secure connections, making it suitable for mass assembly in distribution panels.

    Product Details

    Product Descriprion

    The ALBO RCBOs provide integrated protection against earth leakage, overload, and short circuits in both 1P+N and 3P+N configurations, meeting the requirements of diverse applications from home use to large-scale engineering and wholesale distribution. Compliant with EN IEC 61009-1, they offer a breaking capacity of 6kA and support both B and C tripping characteristics for different inrush conditions. With adjustable sensitivity from 10mA to 300mA and rated currents from 3A to 40A, these devices enable tailored safety solutions for both shock and fire prevention in any installation.

    Designed for 35mm DIN rails with a compact two-module width, the RCBOs feature lug or pin terminals and include clear specifications for conductor cross-sections and tightening torque, supporting consistent assembly in mass-produced distribution panels. They trip within 0.04 seconds at 30mA leakage, ensuring rapid response even in high-demand commercial circuits. With an IP20 rating and slim profile, they are ideal for use in residential and commercial distribution boards to protect sockets, lighting, HVAC, and sensitive equipment in both small-scale and large-scale projects.

    Application

    Standard

    Confirming to EN/IEC 61009-1

    Breaking capacity

    6kA

    Protection

    Ground fault,overcurrent and short circuit

    Rated current,In

    3,6,10,16,20,25,32,40A

    Operating,Ln

    10,30,100,300mA

    Characteristic

    B.C

    Rated residual current operated making & breaking capacity l△m

    500A

    Rated residual non-operated current I△no

    0.5I△n

    Rated impulse withstand voltage Uimp

    4000V

    Number of poles

    1P+N

    Rated voltage

    230VAC

    Protection degree

    -25℃~+40℃

    Residual current off-time

    ≤0.1 sec.

    Type of trip Ground fault Over current

    Electro-magnetic Thermal-magnetic

    Protection degree

    IP20

    Mount

    On 35mm DIN rail

    Width

    2 modules

    Terminal

    Lug type and Pin type

    Type

    AC,A Type B Type

    Curves

    ALBO-6

    Breaking time of residual current

    In(A) I△n (A) Max.Breaking times
    I△n 2I△n 5I△n 5A,10A,20A,50A,100A,200A,
    3~40 0.01,0.03,0.1,0.3 0.1s 0.08s 0.04s 0.04s

    Wiring

    The suitable conductors should be used for connection, see table below for relative parameters.

    Rated current In(A) Cross section area S(mm²) Tightening torque(N.m)
    3~6
    10
    16~20
    25
    32
    40
    1
    1.5
    2.5
    4
    6
    10
    2
    2
    2
    2
    2
    2

    Overall and mounting dimensions

    ALBO-5

    Product display

    ALBO-4P2
    ALBO-4P
    ALBO-2P

    Product video

    Features

    ✅B/C Dual-Curve Protection: Thermal-magnetic tripping for precise overload and fast fault response, stable under continuous commercial/industrial use.

    ✅Customizable Ratings for Projects: 3-40A current ratings + 10-300mA sensitivity, tailored to fit different engineering and wholesale order requirements.

    ✅Reliable Fast Tripping: ≤0.1s certified response, meeting safety standards for both home and large-scale commercial circuits.

    ✅Bulk Assembly Friendly Design: 2-module DIN rail size with universal terminals, ideal for mass production of distribution panels.

    Leave Your Message