Leave Your Message
ELS1 Series Surge Protective Device(AC SPD)
Surge Protective Device

ELS1 Series Surge Protective Device(AC SPD)

This ELECO T2 AC SPD delivers reliable Type 2 surge protection for commercial and industrial applications. Featuring a 40kA discharge capacity, wide operating temperature range (-40℃~+80℃), and clear visual/remote status monitoring, it is engineered for durability and easy maintenance. Available in multiple configurations, it is the ideal, cost-effective protection solution for system integrators and project partners.

    Product Details

    Product Descriprion

    ELS1-AC-DC SPD

    The ELECO T2 is a Type 2/Class II AC Surge Protective Device designed for robust performance in demanding environments. Certified to IEC/EN 61643-11, it utilizes zinc oxide MOV technology to provide a maximum discharge capacity of 40kA (8/20µs), effectively safeguarding electrical systems against transient overvoltages. Its industrial design supports a wide operating temperature range from -40℃ to +80℃ and features a flame-retardant (UL94 V-0) thermoplastic housing with IP20 protection.

    Designed with installers and system integrators in mind, this SPD offers versatile configurations (1P, 2P, 1P+N, 3P, 3P+N, 4P) to match various AC system voltages (275V, 320V, 385V, 440V). Its pluggable design allows for quick installation and replacement on a standard 35mm DIN rail, minimizing downtime. Clear green/red visual fault indication, coupled with an optional remote signaling contact (250V/0.1A), enables proactive system monitoring and maintenance planning.

    We provide more than just components; we offer partnership. As a professional manufacturer, we support your projects with reliable products suitable for a wide range of applications, from data centers and industrial facilities to commercial buildings. We are committed to supporting OEM/ODM requests and bulk project orders, ensuring you receive tailored solutions, consistent quality, and dependable supply for your business needs.

    Application

    Standard

    Confirming to IEC61643-1

    Protection

    Protect electric system and on-loading electrical apparatus from thunder and instantaneous over-voltage

    Ambient temperature

    -40℃ to+80℃

    Number of poles

    2P,3P,4P

    Max. continuousoperating voltage (d.c.)

    AC275V,AC320V,AC385V,AC440V,AC55V

    Response time

    ≤25ns;≤100ns(AC 55V)

    On-Off indicating window

    Green normal function

    Red function-less, immediate replacement required

    Nominal discharge current(8/20us)

    20kA

    Max.discharge current (8/20us)

    40kA

    Type of terminal

    Pin type

    Terminal capacity

    Solid wire cross-section is 1-6mm²

    Stranded wire cross-section is 0.75-4mm²

    Installation

    Mounting on 35mm DIN rail

    Width

    17.5mm per pole

    Protection rating

    IP20

    ELS1 Surge Protective Device

    Type

    Poles

    Uc

    (V)

    In

    (kA)

    Imax

    (kA)

    Up

    (kV)

    Applicable grounding system

    ELS1-D/1-140-5

    1

    140

    5

    10

    <0.8

    Under AC110V and DC

    ELS1-D/1-275-5

    1

    275

    5

    10

    <1.2

    TN-C,IT,TN-S

    ELS1-D/1-320-5

    1

    320

    5

    10

    <1.5

    TN-C,IT,TN-S

    ELS1-D/1-385-5

    1

    385

    5

    10

    <1.8

    TT

    ELS1-D/1-420-5

    1

    420

    5

    10

    <2.0

    TT

    ELS1-D/2-140-5

    2

    140

    5

    10

    <0.8

    Under AC110V and DC

    ELS1-D/2-275-5

    2

    275

    5

    10

    <1.2

    TN-C,IT,TN-S

    ELS1-D/2-320-5

    2

    320

    5

    10

    <1.5

    TN-C,IT,TN-S

    ELS1-D/2-385-5

    2

    385

    5

    10

    <1.8

    TT

    ELS1-D/2-420-5

    2

    420

    5

    10

    <2.0

    TT

    ELS1-D/2Q-385-5

    3

    385

    5

    10

    <2.0

    ELS1-D/3N-275-5

    3

    275

    5

    10

    <1.2

    “3+1” Compage

    ELS1-D/3N-320-5

    3

    320

    5

    10

    <1.5

    “3+1” Compage

    ELS1-D/4-275-5

    4

    275

    5

    10

    <1.2

    TN-C,IT,TN-S

    ELS1-D/4-320-5

    4

    320

    5

    10

    <1.5

    TN-C,IT,TN-S

    ELS1-D/4-385-5

    4

    385

    5

    10

    <1.8

    TT

    ELS1-D/4-420-5

    4

    420

    5

    10

    <2.0

    TT

    Type

    Poles

    Uc

    (V)

    In

    (kA)

    Imax

    (kA)

    Up

    (kV)

    Applicable grounding system

    ELS1-C/1-140-5

    1

    140

    15

    40

    <0.8

    Under AC110V and DC

    ELS1-C/1-275-5

    1

    275

    20

    40

    <1.2

    TN-C,IT,TN-S

    ELS1-C/1-320-5

    1

    320

    20

    40

    <1.5

    TN-C,IT,TN-S

    ELS1-C/1-385-5

    1

    385

    20

    40

    <1.8

    TT

    ELS1-C/1-420-5

    1

    420

    20

    40

    <2.0

    TT

    ELS1-C/1-550-5

    1

    550

    20

    40

    <2.8

    AC380V

    ELS1-C/2-140-5

    2

    140

    15

    40

    <0.8

    Under AC110V and DC

    ELS1-C/2-275-5

    2

    275

    20

    40

    <1.2

    TN-C,IT,TN-S

    ELS1-C/2-320-5

    2

    320

    20

    40

    <1.5

    TN-C,IT,TN-S

    ELS1-C/2-385-5

    2

    385

    20

    40

    <1.8

    TT

    ELS1-C/2-420-5

    2

    420

    20

    40

    <2.0

    TT

    ELS1-C/2Q-320-20

    3

    320

    20

    40

    <1.5

    TN-C,IT,TN-S

    ELS1-C/2Q-385-20

    3

    385

    20

    40

    <2.0

    TN-C,IT,TN-S

    ELS1-D/3N-320-20

    3

    320

    20

    40

    <1.5

    “3+1” Compage

    ELS1-D/3N-385-20

    3

    385

    20

    40

    <1.8

    “3+1” Compage

    ELS1-D/3N-420-20

    3

    420

    20

    40

    <2.0

    “3+1” Compage

    ELS1-D/3-320-20

    3

    320

    20

    40

    <1.5

    TN-C,TN-C-S,TN-S

    ELS1-D/3-385-20

    3

    385

    20

    40

    <1.8

    TN-C,TN-C-S,TN-S

    ELS1-D/3-420-20

    3

    420

    20

    40

    <2.0

    TN-C,TN-C-S,TN-S

    ELS1-C/4-275-5

    4

    275

    20

    40

    <1.2

    TN-C,TN-C-S,TN-S

    ELS1-C/4-320-5

    4

    320

    20

    40

    <1.5

    TN-C,TN-C-S,TN-S

    ELS1-C/4-385-5

    4

    385

    20

    40

    <1.8

    TT

    ELS1-C/4-420-5

    4

    420

    20

    40

    <2.0

    TT

    Type

    Poles

    Uc

    (V)

    In

    (kA)

    Imax

    (kA)

    Up

    (kV)

    Applicable grounding system

    ELS1-B/3-320-3

    3

    320

    30

    60

    <2.0

    TN-C,TN-C-S,TN-S

    ELS1-B/4-320-4

    4

    320

    30

    60

    <2.0

    TN-C,TN-C-S,TN-S

    ELS1-B/3-385-3

    3

    385

    30

    60

    <2.5

    TT

    ELS1-B/4-385-4

    4

    385

    30

    60

    <2.5

    TT

    Type

    Poles

    Uc

    (V)

    In

    (kA)

    Imax

    (kA)

    Up

    (kV)

    Applicable grounding system

    ELS1-D/2+1

    3

    320

    5

    10

    <1.5

    Voltage limit TT

    ELS1-C/2+1

    3

    320

    15

    40

    <1.5

    Voltage limit TT

    ELS1-C/3+1

    4

    320

    5

    10

    <1.5

    Voltage limit TT

    ELS1-C/3+1

    4

    320

    15

    40

    <1.5

    Voltage limit TT

    ELS1-C/3+1G

    4

    320

    15

    40

    <1.5

    Voltage limit TT

    ELS1-B/3+1G

    4

    320

    30

    60

    <1.8

    Voltage limit TT

    Type

    Poles

    Uc

    (V)

    In

    (kA)

    Imax

    (kA)

    Iimp

    (kA)

    Up

    (kV)

    Applicable grounding system

    ELS1-D/2+1

    3

    255

    20

    40

    -

    <1.5

    Voltage switch TT

    ELS1-C/2+1

    3

    255

    40

    -

    12

    <2.0

    Voltage switch TT

    ELS1-D/3+1

    4

    255

    20

    40

    -

    <1.5

    Voltage switch TT

    ELS1-C/3+1

    4

    255

    40

    -

    12

    <2.0

    Voltage switch TT

    ELS1-C/3+1G

    4

    255

    100

    -

    60

    <2.5

    Voltage switch TT

    ELS1-B/3+1G

    4

    255

    100

    -

    60

    <2.5

    Voltage switch TT

    Type

    Technic SG data

    ELS1-D

    ELS1-C

    ELS1-B

    []-140-5

    []-275-5

    []-320-5

    []-385-5

    []-420-5

    []-140-15

    []-275-20

    []-320-20

    []-385-20

    []-420-20

    []-550-20

    []-320-30

    []-385-30

    Max.continuous operationSG vol.(Uc)

    140V

    275V

    320V

    385V

    420V

    140V

    275V

    320V

    385V

    420V

    550V

    320V

    385V

    Level of vol.protection(Up<)

    0.8kV

    1.2kV

    1.5kV

    1.8kV

    2.0kV

    0.8kV

    1.2kV

    1.5kV

    1.8kV

    2.0kV

    2.5kV

    2.0kV

    2.5kV

    NominSG discharge current In(8/20us)kA

    5

    5

    5

    5

    5

    15

    20

    20

    20

    20

    20

    30

    30

    Max discharge current In(8/20us)kA

    10

    10

    10

    10

    10

    40

    40

    40

    40

    40

    40

    60

    60

    ns

    <25

    <25

    <25

    Pole width(mm)

    18

    Colour

    yellow

    gray

    red

    Protection degree

    IP20

    IP20

    IP20

    MetirSG of cover

    PBT

    PBT

    PBT

    Circuit Breaker

    10~16A

    25~32A

    25~32A

    Wiring

    L,N

    2.5~35mm²

    2.5~35mm²

    2.5~35mm²

    PE

    4.0~35mm²

    4.0~35mm²

    4.0~35mm²

    How to select surge protectors

    a. The voltage should be≤Uc;

    b. Up<maximum impulse withstands;

    c. Different protectors should be selected according to various grounding system and protection mode.

    Allocation of surge protectors under TT system

    Allocation-of-surge-protectors-under-TT-system

    ELS1-B series surge protector

    Lightening protection area the boundary between LPZ0 & LPZ1

    Protection category: B

    Over-voltage mounting category: III

    Rated impulse withstand voltage: 4000V

    Parameters of discharge: Uimp and In

    Master power distribution cabinet

    ELS1-C series surge protector

    Lightening protection area the boundary  between LPZ1 & LPZ2

    Protection category: C

    Over-voltage mounting category: II

    Rated impulse withstand voltage: 2500V

    Parameters of discharge: lmax and In

    Branch power distribution cabinet

    ELS1-D series surge protector

    Lightening protection area the boundary between LPZ2 & LPZ3

    Protection category: D

    Over-voltage mounting category: I

    Rated impulse withstand voltage: 1500V Parameters of discharge: Uoc and Isc

    Terminal of power distribution

    Overall and Mounting Dimensions

    Overall-and-Mounting-Dimensions

    Product display

    ELS1-C40D100-2P(right)
    ELS1-C40A385-4P(right)
    ELS1-C40A385-4P(left)

    Features

    1. Ultra-Fast Certified Safety
    Stops surges super fast (<25ms), meets top safety rules to protect machines.

    2. Level-by-Level Shielding
    Special shields guard different areas from big surges to small spikes.

    3. Health Check Lights
    Green/red lights show if working fine or needs changing now.

    4. One-Size-Fits-All Install
    Snaps onto standard rails, works in any building’s wiring system.

    Leave Your Message