SEB Series Smart Miniature Circuit Breaker(Modular Type)
Product Details
Product Descriprion
This versatile smart circuit breaker supports a wide range of configurations from 0.5P to 4P, catering to both single-phase (AC230V) and three-phase (AC380V) applications with a maximum rated current of 80A. It provides robust circuit protection with a rated breaking capacity of 6kA, surge protection up to 4kV, and complies with a rated insulation voltage of 690V.
Its core intelligence lies in advanced data acquisition and protection features. The device performs precise measurements of current, voltage, line temperature, and energy consumption with Class 1.0 accuracy. Protection is comprehensive, covering short-circuit and overload currents, over/under-voltage, phase loss, and three-phase unbalance. Critically, it offers user-configurable earth leakage protection (tripping at 20-30mA) and dual-frequency arc fault detection.
A standout feature is its communication and control flexibility. Equipped with an RS485 interface using the Modbus RTU protocol, it enables seamless integration into building management systems for remote monitoring and control. A dedicated I/O interface accepts 24V DC signals for hardwired functions like fire alarm forced tripping. The physical design includes a rocker switch to toggle between Maintenance (local, read-only) and Operation (remote, read/write) modes, manual test buttons, and a clear status indicator. By combining essential protection with smart grid compatibility, this breaker is ideal for enhancing safety, enabling energy management, and facilitating predictive maintenance in residential and commercial installations.
Application
|
Product Pole Count |
0.5P/1P/2P/3P/4P |
|
Product Specification |
Single-Phase,Three-Phase |
|
Rated Frequency |
50/60Hz |
|
Rated Current |
80A(MAX) |
|
Rated Voltage |
AC230(Single-Phase)/AC380(Three-Phase) |
|
Rated Insulation Voltage |
690V |
|
Rated Impulse Withstand Voltage |
6KV |
|
Rated Ultimate Short-Circuit Breaking Capacity |
6KA |
|
Rated Service Short-Circuit Breaking Capacity |
6KA |
|
Surge Protection |
4KV |
|
Fire Alarm Linkage |
Fire Alarm Forced Trip |
|
Protection Functions |
Current Protection,Voltage Protection,Earth Leakage |
Wiring
|
Rated Current (A) |
Conductor Cross-Sectional Area (mm²) |
|
1/2/4/6 |
1.0 |
|
10 |
1.5 |
|
16-20 |
2.5 |
|
25 |
4 |
|
32 |
6 |
|
40-50 |
10 |
|
63 |
16 |
|
80 |
25 |
Product Model Number and Meaning
①:Terminal Block
②:Test Button
③:Test Indicator Light
④:On/Off Status Indicator
⑤:Maintenance/Operation Status Switch Key
⑥:Power Indicator Light
⑦:Operating Lever
⑧:Communication DIP Switch
⑨:SN Code
|
Specification Item |
Description / Function |
|
RS485 Interface |
Protocol:Standard Modbus RTU |
|
IO Interface |
Accepts 24V DC signals for local (hardwired) control and fire system interlocking,used for executing Close (ON) and Trip (OFF) commands. |
|
Push Buttons |
Test/Operate Mode Selector (rocker switch). |
|
Toggle Switch (Mode Selector) |
Maintenance Mode:Read-only data access;remote control is disabled. |
|
Operating Handle / Mechanism |
Indicated Positions:TRIPPED (OFF),ON (Closed). |
|
Function Category |
Item |
Specification |
|
Data Acquisition |
Arc Fault Detection |
Dual-frequency detection (high + low). (Not available for 380V rated voltage products) |
|
Energy Metering |
Class 1.0 accuracy (per GB Standard) |
|
|
Earth Leakage Detection |
Unit: mA (milliampere), Range: 0-2000mA (Residual Current Detection Function) |
|
|
Current Detection |
Unit: A (Ampere), Resolution: 1 decimal place |
|
|
Voltage Detection |
Unit: V (Volt), Resolution: 1 decimal place |
|
|
Line Temperature Detection |
Unit: °C (Celsius), Resolution: 1 decimal place |
|
|
Open/Close Status Detection |
Open status; Closed status; Open/Close locked status; Unlocked status |
|
|
Mode Switch Detection |
Maintenance Mode (Local); Operation Mode (Remote) |
|
|
Protection Features |
Current Protection |
Short-Circuit Protection |
|
Overload Protection |
||
|
Voltage Protection |
Over-Voltage / Under-Voltage Protection |
|
|
Phase Loss Protection (Three-Phase) |
||
|
Three-Phase Unbalance Protection |
||
|
Phase Sequence Reversal Protection (Three-Phase) |
||
|
Earth Leakage Protection |
No trip at 15mA leakage (User-configurable) |
|
|
Trip at 20-30mA leakage (User-configurable) |
||
|
Earth Leakage Circuit Breaker Self-Test (User-configurable) |
||
|
Temperature Protection |
Alarm at >60°C, Trip at 75°C |
|
|
Power Limiting |
User-configurable power limit |
|
|
Arc Fault Protection |
Arc fault alarm and protection |
|
|
External Communication |
RS 485 Communication |
Protocol: GB/Z19582.1-2004; Refer to RS Communication Protocol |
|
Communication Protocols |
Modbus RTU, MQTT, DL/T645 |
|
|
Firefighting Interlocking I/O Interface |
Integration with fire alarm system for control, scenario interlocking, local hardwired control |
|
|
PLC Power Line Carrier |
PLC carrier model requires a compatible carrier gateway for communication |
|
|
Remote Control |
Remote Close/Open Operation |
|
|
Safety Strategy Configuration |
Breaking Capacity |
Housing and actuator mechanism supplied by vendor; PCB and interfaces provided by client. |
|
Contacts |
Actual breaking capacity ≥6000A (subject to manufacturer's specifications). Arc chute uses standardized parts with chrome-plated metal plates, thickness >0.8mm. |
|
|
Load Current |
Manufacturer-supplied, silver alloy contacts. Configured per national standards for load and breaking cycle count. |
|
|
Overload Protection |
Actual load current rating not less than 63A/80A. Contacts maintain normal temperature at 63A/80A load test. Electronic current limiting (IC-based). |
|
|
Short-Circuit Protection |
Standard circuit breaker precision for 63A/80A overload protection. Electronic current limiting (IC-based) set below 63A/80A. |
|
|
Line/Load Terminals |
Rated to 63A/80A standard, accepts up to 10mm² wire per national standard. Terminal fasteners blue-zinc plated. Internal connections use high-temperature silicone-coated braided copper wire, soldered. |
|
|
Alarm Notification |
APP Push Notification |
|
|
Self-Test Function |
Self-Test |
Wiring Diagram for Three-Phase Combined Unit
Wiring Diagram for Three-Phase, 4-Pole System
Wiring Diagram for Single-Phase, 2-Pole System
Product display